SCU224
backward
forward
SET
(selection / adjustment mode)
The system monitoring display consists of 3 blocks: indica-
tion of the channel, tool bar and system screen (active
system scheme).
The indication channel consists of two lines. The upper
line is an alphanumeric 16-segment indication in which mainly
the channel names / menu items are shown. In the lower
7-segment indication, the channel values and the adjustment
parameters are indicated.
Temperatures are either indicated in °F or °C, whereas
temperature differences are indicated in K or °Ra respec-
tively.
2.2.1 Channel indication
indication channel only
2.2.2 Tool bar
The additional symbols of the tool bar indicate the current
system status.
tool bar only
2. Operation and function
2.1 Pushbuttons for adjustment
2.2 System monitoring display
Full Monitoring-Display
Symbol standard blinking
relay 1 active
relay 2 active
maximum tank limitation
active / maximum tank
temperature exceeded
collector cooling function or
recooling function active
antifreeze- function activated
collector minimum limitation
or antifreeze function active
collector security shutdown or
tank securtiy shutdown active
+
sensor defect
+
manual operation active
an adjustment channel is
changed SET-mode
+
OK
The controller is operated by 3 pushbuttons below the
display. The forward-key (+) is used for scrolling forward
through the indication menu or to increase the adjustment
values. The backwards-key (–) is accordingly used for the
reverse function.
For adjustment of last indication channel, keep button +
pressed for 2 seconds. If an adjustment value is shown on
the display, SEt is indicated. In this case you can press the
key „Set“ (OK) in order to change into input mode.
Select a channel by keys – and +
Shortly press key OK, so that „SEt“ flashes
Adjust the value by keys – and +
Shortly press key OK, so that „SEt“ permanently appears,
the adjusted value is now saved.