Viessmann VITOCELL 100-V Instrukcja Obsługi Strona 16

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 24
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 15
16
5608 487 v1.2
Vitocell 100-V Installation Instructions
Domestic Water Connections
Set-up and Connections
Use a Loctite 55 string and pipe dope on all threaded
nipples on tank.
IMPORTANT
Note: - Connect all pipe work with detachable fittings.
- Seal connections that are not required with red
brass caps.
- Equip the DHW circulation pipe with circulation
pump, check valve and time switch. Gravity
operation is only feasible to a limited degree.
- Always install DHW group of tanks with
connected DHW circulation.
1. Pipe together boiler and tank as illustrated. Connections
must be accessible for service (use factory supplied
adaptors).
2. Insulate domestic hot water supply piping.
Legend
A Spring-loaded flow check valve
B Discharge pipe
C Anti-scald tempering valve (field supplied)
SV Shut-off valve
FV Flow check valve
PR Pressure reducing valve
D Drain
DCW Cold water supply lines
PGC Pressure gage connection
E Precharged expansion tank (required where
backflow preventer is installed; check local
plumbing codes and requirements)
BP1 Backflow preventer
BP2 Backflow preventer
T&P Temperature and pressure relief valve
DW Water filter
DHW Domestic hot water supply
RP Recirculation pipe
RPU Recirculation pump
IMPORTANT
This is a simplified conceptual drawing only! Piping and
necessary componentry must be field verified. Proper
installation and functionality in the field are the responsibility
of the heating contractor.